XC3000 | XC4000E | XC4000X | XC5200 | XC9000 | Spartan | SpartanXL | Spartan2 | Virtex |
---|---|---|---|---|---|---|---|---|
Macro | Macro | Macro | Macro | Macro | Macro | Macro | N/A | N/A |
X74_163 is a 4-stage, 4-bit, synchronous, loadable, resettable, cascadable binary counter. The active-Low synchronous reset (R), when Low, overrides all other inputs and resets the data outputs (QD, QC, QB, QA) and the ripple carry-out output (RCO) Low during the Low-to-High clock (CK) transition. When the active-Low load enable (LOAD) is Low and R is High, parallel clock enable (ENP) and trickle clock enable (ENT) are overridden and the data on inputs (A, B, C, D) is loaded into the counter during the Low-to-High clock (CK) transition. The outputs (QD, QC, QB, QA) increment when LOAD, ENP, ENT, and R are High during the Low-to-High clock transition. The counter ignores clock transitions when LOAD is High and ENP or ENT are Low; RCO is High when QD - QA and ENT are High.
The carry-lookahead design accommodates large counters without extra gating. Refer to Carry-Lookahead Design in the X74_160 section for more information.
Inputs | Outputs | ||||||
---|---|---|---|---|---|---|---|
R | LOAD | ENP | ENT | D - A | CK | QD - QA | RCO |
0 | X | X | X | X | 0 | 0 | |
1 | 0 | X | X | D - A | d - a | RCO | |
1 | 1 | 0 | X | X | X | No Chg | RCO |
1 | 1 | X | 0 | X | X | No Chg | 0 |
1 | 1 | 1 | 1 | X | Inc | RCO | |
RCO = (QDQCQBQAENT) d - a = state of referenced input one setup time prior to active clock transition |